Close Call Alert: Truck Makes Contact with Powerline

May 21, 2018 Tara

Surface – Limestone– On April 5, 2018, a concrete pumper truck made contact with a 13.2 KV overhead powerline. The powerline broke and fell on the cab of a tractor trailer truck. The driver of the tractor trailer remained inside the cab of the truck until the powerline was de-energized. This close call accident resulted in no injuries.

Best Practices

• Overhead high-potential powerlines shall be installed as specified by the National Electrical Code.
• High-potential powerlines should be visually examined by the mine operator to determine if clearances over roadways, parking lots, walkways or other areas accessible to people may create a hazard.
• Clearances of high-potential powerlines above roadways, parking lots and walkways should generally be greater than 18.5 feet.
• Locate all overhead powerlines during a workplace examination.
• Keep people and equipment 10 feet away from all overhead powerlines.
• Lower equipment apparatus before driving under overhead powerlines.
• Do not touch anything that is in contact with an overhead powerline.
• Stay at least 35 feet away from fallen powerlines.
• If a powerline has fallen within 35 feet of your location, and you are not exposed to direct contact, do not move until power is removed. Step potential can be fatal or cause serious injury.

Previous Article
Seven Golden Rules for Prospecting
Seven Golden Rules for Prospecting

Prospecting is a popular pastime in Western Australia, with everyone from tourists to professional prospect...

Next Article
Dangerous incident: Spontaneous Combustion at Mine Site
Dangerous incident: Spontaneous Combustion at Mine Site

Summary: Spontaneous combustion was developing at a mine site and reported to the regulator. Oxidised coal ...