Mechanic sustained serious hand injuries

February 25, 2021 Mining Editor

The Department of Western Australia, the Department of Mines, Industry Regulation and Safety has released a safety alert regarding a mechanic who had serious hand injuries when serviced a generator.

On 29 October 2020, a contractor service mechanic serviced a generator that provided power to a mining village. The generator was on a hire agreement with a third party supply company, which is a common arrangement for mines in Western Australia.

Worker suffers arm injury at underground metal mine

Report into the serious injury of a worker at Appin North Mine

The service mechanic completed a general service of the 300 kVA generator, desolated it and brought it back on-line. He then conducted post-service inspections and clean-up, including wiping up oil and grease marks with a rag.

When the service mechanic leaned into the generator enclosure with a rag in his hand, it appears the rag and his hand were drawn into the rotating radiator fan blades causing serious injuries to his thumb, index and middle fingers.

The Regulator indicates the contributing factors are:

  • The service mechanic was cleaning up inside the generator enclosure with the engine running. There was a gap in the underside of the guarding around the radiator fan.
  • It is possible for a loose rag to be drawn into the fan blades thereby pulling a hand in through the gap in the guarding to contact the moving blades.
  • Risk assessments conducted by duty holders had not identified the risk of entanglement posed by the gap in the fan guarding.
  • The work procedure for servicing and inspecting the generator was not clear in terms of job sequence and isolation requirements.
  • Monitoring processes were not undertaken to confirm that standards/safe work procedures were followed (e.g. audit, task observations, site inspections).

The Regulator request the following actions will assist in the safe operation of generators.

  • Duty holders (i.e. designers, manufacturers, suppliers, employers, etc.) must undertake risk assessments on all generators to identify, assess and control all hazards to which workers are likely to be exposed.
  • When choosing hazard controls, select the highest practicable control measures considering the hierarchy of controls and human and organisational factors (in particular, human error).
  • Duty holders must ensure that guarding and other access controls prevent inadvertent contact from moving machine parts. Inadvertent contact can mean unintended contact in the course of performing work activities and is not only due to a slip or trip event.
  • Implement and enforce suitable isolation procedures for maintenance, servicing and cleaning of generators. The procedures must include de-energising plant and the lock, tag and try/test method.
  • Develop safe work procedures for all tasks associated with operating and servicing generators in clear, unambiguous language.
  • Confirm workers receive adequate supervision in the performance of their duties while operating and maintaining the plant.
  • Confirm that workers conducting cleaning, maintenance and repair work are adequately instructed, trained and assessed as competent.
  • Establish robust contractor management processes to ensure adherence to required standards and safe systems of work.
  • Implement regular and ongoing monitoring programs and processes to ensure adherence to safe work procedures.
  • Ensure persons working around moving equipment with moving parts do not have loose items of clothing, unsecured hair or other items that could be caught by moving parts.

Read more Mining Safety News

Previous Article
Competition for mining investment requires urgent policy reforms
Competition for mining investment requires urgent policy reforms

The release of the Fraser Institute’s Annual Survey of Mining Companies has sounded the alarm on the need f...

Next Article
TPV-11 PUMP RANGE – Made for Mining
TPV-11 PUMP RANGE – Made for Mining

The TIDAL FLUID POWER TPV-11 is an Open Circuit Pump with a Nominal pressure of 350 Bar and a peak pressure...